Regulatory Helpdesk: March 5

Batteries, Batteries, and more Lithium Batteries

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Why do I need an SDS for a Laptop Battery?

Q. We are shipping used laptops with batteries in the units from the US to HK via air. There are multiple manufacturers and models, are (M)SDS sheets required for each model? Our forwarder is requesting them in order to provide pricing.
A. To answer your question, it would depend on why the forwarder is requesting them. They may be asking for them to meet the written emergency response requirements. However, they could be asking for them for classification purposes to prove which part of the packing instructions these meet.

The SDS could tell them the watt-hour rating which would then drive which part of the instruction to use. Forwarders and carriers have a lot of leeway. I can only speak to what the regulations say. There is nothing in 49 CFR or IATA that indicates you must use an SDS. Most people tend to default to them because they meet so many parts of the regulations in one place.

Manufacturer’s Packaging (Lithium Battery)

Q. Should I remove the manufacturer’s packaging from lithium ion batteries being shipped by air under PI 965 Continue Reading…
Regulatory Helpdesk: February 19 & 26

Shipments to Puerto Rico, Non-hazardous substances, the Overpack label, and Aviation Regulated Liquids or Solids

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Shipping to Puerto Rico

Q.  If 49 CFR is used to make a vessel shipment of limited quantities from the mainland US to Puerto Rico is a shipping paper required? I’m asking because limited quantities don’t require shipping papers.

A. Technically that is true. Shipping papers are not needed for US GROUND shipments. You have to read the fine print in paragraph 173.150(b) which is the section on limited quantities for flammable and combustible liquids. It that paragraph it says, ” … is not subject to the shipping paper requirements of subpart C of part 172 of this subchapter, unless the material meets the definition of a hazardous substance, hazardous waste, marine pollutant, or is offered for transportation and transported by aircraft or vessel, and is eligible for the exceptions provided in §173.156 of this part“.

Non-hazardous substances under WHMIS 2015

Q.Customer called and asked if SDS’s were required for non-hazardous substances and where to find this in the WHMIS 2015 Regulations?

A.The answer to your question can be found below in WHMIS 2015, which states that safety data sheets only pertain to a hazardous product, therefore Continue Reading…

Regulatory Helpdesk: February 12

Lithium Batteries, Placards, and SDS in the Workplace

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Lithium Batteries (Air)

Q. For PI 967 in IATA is the weight limit the weight of the equipment and battery inside of it or just the battery.
A. For all battery packing instructions in IATA it is always the weight of the battery itself.

Lithium Batteries (IMDG)

Q. Do “excepted” batteries require segregation from limited quantity packages under IMDG?
A. Under IMDG §3.4.4.2 it tells you that segregation requirements in Chapters 7.2 – 7.7 plus any information on Stowage in column 16b of the table do not apply to goods in limited quantity packages. Lithium ion batteries do not yet need segregation under IMDG either. It is only IATA that has implemented segregation this year as part of the packing instructions for shippers. IATA has also added batteries to the segregation table for operators, but it isn’t mandatory until next year and only applies to those in Section 1A and 1B not Section II.

Placards (TDG)

Q. Customer asked if his Class 8 material (UN 1830) needed to have a UN number on the placard if shipping 1 liter per package and 7 per tote for a total of 17 Liters for the shipment in Canada. Continue Reading…
Regulatory Helpdesk: February 5

Labels, Placards, Segregation, Documentation, SDSs & Emergency Response

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Here are the top 6 questions from last week.

SDS and Workplace Labels

Q. If I have a product like a concentrated cleaner which is corrosive to the eyes and skin that I water down at my facility, do I need a new SDS and workplace labeling?
A. You have 2 options. You can use the SDS as provided to create your workplace labeling. This may cause concern with your workers. However, it would be better for you to develop your own and re-evaluate the product using the hazards presented in the watered-down version. It is possible, depending on how diluted it is, to move into the irritation or non-hazardous range.

Listing Canutec or Chemtrec on Lithium Battery Marks

Q. Regarding the new battery mark, am I allowed to add “in case of emergency, contact Chemtrec”?
A. The regulations are pretty clear (DOT §173.185(c)(3) and IATA 7.1.5.5). What should be listed there is a phone number for “additional information”. There should be no extra phrasing other than phone number itself. As for listing Chemtrec, Infotrac or even Canutec, those are 3rd party Emergency Response Providers and would not be appropriate to include in that section of Continue Reading…
Regulatory Helpdesk: January 29

WHMIS Labels Format, How ICAO and IATA are Related, Shipping Residues, and IATA Documentation

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

WHMIS Labels Format

Q. Is there a specified format for WHMIS 2015 workplace labels?
A. No. The information is specified but not the format. Pictograms may assist employees in quickly identifying the hazards/precautions; and may simplify employer creation of substitute “supplier” labels.

This is especially true when employees have been trained in the GHS-based WHMIS 2015 system. Employers must ensure training has been provided if GHS pictograms are used on workplace labels during the transition period.

ICAO/IATA Relationship

Q. Is a risk of non-compliance in using IATA DGR given that government regulations specify compliance with ICAO Technical instructions?
A. IATA DGR states in §1.14 that they contain all of the ICAO TI requirements and add additional restrictions. Thus, complying with IATA DGR will ensure compliance with ICAO TI. As with all regulations, it is important to keep aware of amendments/corrigenda between publication dates.

Shipping Residues (TDG)

Q. When we are shipping residues…. Can we and how do we indicate ‘Residue last contained’ on the transport document.
A. If the quantity of dangerous goods in a means of containment is less than 10 per cent of the Continue Reading…
Regulatory Helpdesk: January 22, 2018

Shipping Alkaline Batteries, IBC Pressure Gauges, and SDS Expiry Under WHMIS 2015

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Shipping Spent Alkaline Batteries (49 CFR)

Q. Can spent alkaline batteries (Duracell) be shipped to a recycling facility by ground without being declared dangerous goods?
A. Assuming that these are dry alkaline batteries that are used or spent for recycling, they are not required to be shipped as dangerous goods by ground in the USA per 172.102 Provision 130 (d) provided they are rated under 9 volts per below.

Ground Transport (US DOT): 49 CFR 172.102 SPECIAL PROVISION 130

Used or spent battery exception. Used or spent dry batteries of both non-rechargeable and rechargeable designs, with a marked rating up to 9-volt that are combined in the same package and transported by highway or rail for recycling, reconditioning, or disposal are not subject to this special provision or any other requirement of the HMR.

Pressure Gauge Requirements for IBCs

Q. What are the pressure gauge testing requirements for 31A IBCs?
A. I referred the customer to 178.814 d (1) (2) which lists 2 consecutive tests that must be administered with a rating of 65kPa first followed by 200kPa.

Can You Use Capital Letters (TDG)?

Q. Do Continue Reading…
Regulatory Helpdesk: January 15, 2018

Here are the top 4 questions last week:

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Worded Label Requirements

Q. Are worded labels required for use in US transport?
A. Based on 172.405(a), except where prescribed, wording is optional on US hazard class labels.

Placement of UN Number, Shipping Name and Hazard Class Label

Q. Can you put the “ISH” information (shipping name, UN number and hazard label) on the top of a package (e.g. box)?
A. That depends. Different regulations express it differently, but the key message is that the information must be easily located and read; and with few exceptions in proximity to each other on the same surface of the package. All common regulations (49 CFR, Canadian TDGR, IATA DGR, IMDG Code) have a general requirement for legibility.

49 CFR requires the information to be clearly visible on a surface other than the bottom [172.304(f) and 172.304(a)(i)]- so the top could be allowed if the configuration resulted in it being clearly visible.

IATA DGR and the IMDG Code do not specify top/bottom but only require the information to be “readily visible” [IATA 7.2.6.1(a); IMDG 5.2.1.2.1, 5.2.2,1.6].

TDGR, however, is a little more prescriptive- requiring the information to be “on any side … other than the side on Continue Reading…

Regulatory Helpdesk: January 8, 2018

3 Questions from our Regulatory Helpdesk

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. We’re here to help you become independent with – and understand the whys and hows – of the regulations.

Disclosing Concentration Ranges Under WHMIS 2015

Q. Do I have to indicate “Proprietary” on a WHMIS (M)SDS when masking actual concentrations with ranges?
A. It depends. WHMIS 1988 accepted the use of concentration ranges on MSDS to mask confidential business information (CBI) without requiring any indication.

WHMIS 2015 does not currently allow the use of ranges other than the concentration range actually present for a variable substance (also, unlike WHMIS 1988, ranges cannot be used to allow a single SDS for a series of different but similar products).

Products subject to an approved masking under the HMIR Act do have to, in both versions, reference the exemption authorization on the (M)SDS.

A CBI amendment under consideration may re-introduce the permissible use of ranges to unilaterally mask actual concentrations. This proposal as currently written requires a statement in the SDS when a range is used that’s wider than the actual concentration range, to protect CBI. We’ll have to wait for the final amendment to answer the question going forward …

IMDG or TDG?

Q. Does a shipment within Canada by vessel from Newfoundland require placarding according to the IMDG Code or do the provisions of the TDGR Continue Reading…
Regulatory Helpdesk: January 1, 2018

3 Questions from our Regulatory Helpdesk

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. Check back weekly, the helpdesk rarely hears the same question twice.

Location of the To/From Address

Q: Can the name and address of the shipper and/or receiver be on top of packages of hazardous materials?
A: For 49 CFR only 1 address is needed and for air you would need both. Ocean doesn’t specifically mention addresses but we tend to include one since most carriers are going to ask for it. None of the regulations actually state where they MUST go. In some of our older trainings it was indicated that the addresses had to be near the name and number. I’ve tried to correct that.

  • For Air – Section 7.1.4.1(b) – both addresses “located on the same surface of the package near the proper shipping name mark, if the package dimensions are adequate
  • 49 CFR – Only one address is required per 172.301(d)
  • IMDG – There are no set guidelines for including addresses in Section 5.

New Segregation of Lithium Batteries

Q: Do lithium batteries have to be segregated?
A: It depends on the mode of transport.

In 49 CFR and IMDG 38-16, there are no segregation requirements for batteries. There could be information on a batteries SDS that should be followed.

For Air, in the new 59th edition of IATA or as some call it the 2018 version, there is some Continue Reading…

Regulatory Helpdesk: December 25

Lithium Batteries & Hazard Communication

Welcome back to the Regulatory Helpdesk where we answer your dangerous goods & hazmat questions. Due to the Holiday week, we have only 2 FAQ’s worth sharing.

Check back weekly, the helpdesk rarely hears the same question twice.

More Lithium Batteries

Q. We want to ship a 63 W-hr lithium ion battery.  Are there any issues with packaging 2 or more together in the same container under IATA 2018 and 49CFR?  If 2 or more are ok what is the limit?
A. Under IATA you have 2 options and it will be up to you as the shipper to make the decision as to how to handle your shipment. As you know the 65 w-h battery falls into the excepted type. Now, for IATA that puts you in either Section II or Section IB. By the way, be sure to grab the recently published Addendum!

For Section II batteries there is a change for this year. As per usual, there are several changes to the operator regulations. Also, these batteries cannot be packed in the same outer packaging as any other dangerous goods. 

The rest of the section still applies in PI 965. You are not allowed to offer more than 1 package prepared under Section II in any single consignment or shipment.

If you are using an overpack, you can only have one package of these batteries in the overpack. The overpack cannot Continue Reading…